Jawa Barat - Bekasi

Fluke 1587/ET Advanced Electrical Troubleshooting Kit

Harga :
CALL
Merk :
FLUKE
Pengiriman :
3 hari sejak pembayaran
Lokasi :
Jawa Barat - Bekasi
Dilihat :
38 Kali
Update Terakhir :
09-09-2016 10:42

Dapatkan Spesifikasi Harga Fluke 1587/ET Advanced Electrical Troubleshooting Kit Produk Terbaik dari Andalan Prima General Supplier,Test & Measuring Instrument,Laboratory Equipment , Glassware & Chemical

Detail Produk

Fluke 1587 Insulation Multimeters

Specifications
Voltage DC Maximum voltage 1000 V
Accuracy ±(0.09% + 2)
Maximum resolution 0.001V
Voltage AC Maximum voltage 1000 V
Accuracy ±(2% + 3)
AC bandwidth 5 kHz1
1. With low pass filter; 3 db @ 800 Hz
Maximum resolution 0.1 mV
Current DC Maximum amps 400 mA
Amps accuracy ±(0.2% + 2)
Maximum Resolution 0.01 mA
Current AC Maximum amps 400 mA
Amps accuracy ±(1.5% + 2) 1
1. 1 kHz bandwidth
Maximum resolution 0.01 mA
Resistance Maximum resistance 50 MΩ
Accuracy ±(0.9% + 2)
Maximum resolution 0.1 Ω
Capacitance Maximum capacitance 9,999 µF
Accuracy ±(1.2% + 2)
Maximum resolution 1 nF
Frequency Maximum frequency 100 kHz
Accuracy ±(0.1% + 1)
Maximum resolution 0.01 Hz
Temperature measurement -40.0°C to 537°C
-40.0°F to 998°F
excluding probe
Diode test Range 6 V
Resolution 1 mV
Accuracy ±(2% + 1)
Insulation Test
Minimum test current @ 1 kΩ/V 1 mA
Test voltages 50, 100, 250, 500, 1000 V
Maximum resistance per test voltage 50 V
100 V
250 V
500 V
1000 V 2 GΩ
Maximum resolution per test voltage 50 V 0.01 MΩ
100 V 0.01 MΩ
250 V 0.1 MΩ
500 V 0.1 MΩ
1000 V 0.1 MΩ
Accuracy per test voltage 50 V ±(3% + 5)
100 V ±(3% + 5)
250 V ±(1.5% + 5)
500 V ±(1.5% + 5)
1000 V ±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600 MΩ
Environmental Specifications
Operating temperature –20°C to +55°C
Storage temperature -40°C to +60°C
Humidity (without condensation) 0% - 95% (10°C – 30°C)
0% - 75% (30°C – 40°C)
0% - 40% (40°C – 55°C)
Operating altitude 2000 m
Safety Specifications
Overvoltage category Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency approvals 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Mechanical and General Specifications
Size 203 x 100 x 50 mm (with holster)
Weight 624 g
Warranty 3 years
Battery life Alkaline Meter use 1000 hours
Insulation test use Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP Rating IP40

Fluke i400 AC Current Clamp

Specifications
Nominal current range 400 A
Continuous current range 1 A - 400 A
Maximum non-destructive current 1000 A
Lowest measurable current 1 A
Basic accuracy 2% + 0.06 A 
(45 - 400 Hz)
(% reading + floorspec)
Useable frequency 5 Hz - 20 kHz
Output level(s) 1 mA/A
Safety Specifications
Safety CAT IV 600 V, CAT III, 1000 V
Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010
Mechanical and General Specifications
Warranty 1 year
Maximum conductor diameter 32 mm (1.25 in)
Maximum conductor size (busbar) 750 MCM
Output cable length 1.5 m (59 in)
Shrouded banana plugs Yes

Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature range -30°C to 650°C (-22°F to 1202°F)
Accuracy ±1.0°C or ±1.0% of reading, whichever is greater
-10°C to 0°C: ±2.0
-30°C to -10°C: ±3.0
Response time (95%) Fluke 62 MAX+ < 300 ms (95% of reading)
Spectral response 8 to 14 microns
Emissivity 0.10 to 1.00
Optical resolution 12:1 (calculated at 90% energy)
Display resolution 0.1°C (0.2°F)
Repeatability of readings ±0.5% of reading or < ±0.5°C (1°F), whichever is greater
Power AA battery
Battery life 8 hours with laser and backlight on
Physical specifications Weight 255 g (8.99 oz)
Size 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-4°F to 140°F), (without battery)
Operating humidity 10% to 90% RH non-condensing at 30°C (86°F)
Operating altitude 2000 meters above mean sea level
Storage altitude 12,000 meters above mean sea level
IP rating IP 54 per IEC 60529
Drop test 3 meters
Vibration and shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006
Standards and agency approval Compliance EN/IEC 61010-1: 2001
Laser safety FDA and EN 60825-1 Class II
 

Permintaan Penawaran