Jawa Barat - Bekasi

HACH TU5300 sc Low Range Laser Turbidimeter, EPA Version

Harga :
CALL
Merk :
HACH
Pengiriman :
3 hari sejak pembayaran
Lokasi :
Jawa Barat - Bekasi
Dilihat :
175 Kali
Update Terakhir :
02-09-2016 14:07

Dapatkan Spesifikasi Harga HACH TU5300 sc Low Range Laser Turbidimeter, EPA Version Produk Terbaik dari Andalan Prima General Supplier,Test & Measuring Instrument,Laboratory Equipment , Glassware & Chemical

Detail Produk

 

Specifications

Accuracy:±2% of reading plus 0.01 NTU from 0 to 40 NTU
±10% of reading from 40 to 1000 NTU based on Formazin primary standard
Cable Length:1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories
Calibration Method:For Formazin and Stablcal®: 
20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range

Custom calibration for up to 6-point calibrations
Certifications:CE compliant
US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version
Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Australian RCM Marking
Communication:None
Dimensions (H x W x D):249 mm x 268 mm x 190 mm
Fitting type:Sample quick connector: ¼-in. for ¼-in. tubing
Light Source:Class 2 laser product, with embedded 650 nm (EPA) or 850 nm (ISO), max. 1.0 mW Class 2 laser source (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Lower Limit of Detection (LOD):0.002 NTU
Material:ASA Luran S 777K / RAL7000, TPE RESIN Elastocon® STK40,
Thermoplastic Elastomer TPS-SEBS
Mounting Configurations:Wall Mount
Operating Humidity:Relative humidity: 5 to 95% at different temperatures, non-condensing
Operating Temperature Range:0 to 50 °C (32 to 122 °F)
Options:Process Head Only
Range:EPA:
0 to 700 NTU / FNU / TE/F / FTU
0 to 175 EBC

ISO:
0 to 1000 NTU / FNU / TE/F / FTU
0 to 250 EBC
Regulatory:EPA
Repeatability:Better than 1% of reading or ±0.001 NTU on Formazin at 25 °C (77 °F), whichever is greater
Resolution:0.001 NTU / FNU / TE/F / FTU / EBC
Response Time:T90<30 seconds at 100 mL/min
Sample Flow Rate:100 to 1000 mL/min; optimal flow rate: 200 to 500 mL/min
Sample Pressure:6 bar (87 psi) maximum, compared to air at sample temperature range from 2 to 40 °C (35.6 to 104 °F)
Sample Temperature:2 to 70 °C (35.6 to 158 °F)
Signal Average Time:5 to 90 seconds (default: 30 seconds)
Storage Conditions:-40 to 60 °C (-40 to 140 °F)
Stray Light:<10 mNTU
Units:NTU, FNU, TE/F, FTU, EBC
Verification:Liquid: Stablcal®, Formazin (0.1 to 40 NTU)
Dry: Glass Rod at<0.1 NTU
Warranty:1 year
Weight:5.95 lbs. (2.7 kg) (11lbs. (5.0 kg) with all accessories)

Permintaan Penawaran

Leedoo Sandal Pria Sandal Casual Santai Kekinian Sepatu Sendal Fashion Pria Anti Slip MT402
Leedoo Sandal Pria Sandal Casual Santai Kekinian Sepatu Sendal Fashion Pria Anti Slip MT402
Rp. 97.500
BAGSMART Fashion Tote Bag Wanita Shoulder Bag Bowknot Ringan Puffy Tas Kuliah Tahan Air Multifungsi Bagsmart Official Shop
BAGSMART Fashion Tote Bag Wanita Shoulder Bag Bowknot Ringan Puffy Tas Kuliah Tahan Air Multifungsi Bagsmart Official Shop
Rp. 351.000
ANCEL VC300 CAN OBD2 Scanner Code Reader Car Check Engine Automotive Diagnostic Tool Supports All OBD II Protocols
ANCEL VC300 CAN OBD2 Scanner Code Reader Car Check Engine Automotive Diagnostic Tool Supports All OBD II Protocols
Rp. 269.000
WTHB Outdoor Tenda Kemah Camping Nyaman 3-4 Orang Otomatis Tenda Lipat Portable Tenda Gunung Waterproof
WTHB Outdoor Tenda Kemah Camping Nyaman 3-4 Orang Otomatis Tenda Lipat Portable Tenda Gunung Waterproof
Rp. 311.000
MIXIO S16Pro Mic Wireless Microphone Profesional Mikrofon Lavalier Mixio Official Store
MIXIO S16Pro Mic Wireless Microphone Profesional Mikrofon Lavalier Mixio Official Store
Rp. 293.000
Samsung MG23K3505AK Microwave Grill 23 L Praktis Ekonomis Samsung Official Store
Samsung MG23K3505AK Microwave Grill 23 L Praktis Ekonomis Samsung Official Store
Rp. 1.150.000