High Accuracy, High Performance and Reliable Measurements |
• |
0.09% basic DC accuracy |
• |
Large display with 6,000 counts |
• |
True-RMS Measurements |
• |
True-RMS or MEAN value detection mode can be selected * |
• |
Low-pass filter for motor drive measurements |
• |
User calibration function |
 |
Safety design for industrial use |
• |
Complies with IEC 61010-1 CAT IV 600V,
CAT III 1000V |
• |
Terminal shutter to prevent incorrect test leads' insertion in current terminals |
• |
Very wide operating temperature range from
-10 to 55ºC |
|



(Photo: 1052) |
 |
Reliable support for data management * |
• |
Large data internal memory * |
|
 |
KEW 1052: 1,600 data (logging), 100 data (manual) |
• |
Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set) * |
 |
* Only for KEW 1052 |
* MAX 32,767 data can be transferred. |
|
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
KEW 1051 |
 |
 |
 |
KEW 1052 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Detection mode |
 |
 |
 |
RMS |
 |
 |
 |
MEAN/RMS (switch) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
DC V |
 |
 |
 |
600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])

|±0.09%rdg±2dgt (Basic accuracy) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
AC V [RMS] |
 |
 |
 |
600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])

|±0.5%rdg±5dgt (Basic accuracy) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
DC A |
 |
 |
 |
600.0/6000µA/60.00/440.0mA/6.000/10.00A

|±0.2%rdg±2dgt (Basic accuracy) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
AC A [RMS] |
 |
 |
 |
600.0/6000µA/60.00/440.0mA/6.000/10.00A

|±0.75%rdg±5dgt (Basic accuracy) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Ω |
 |
 |
 |
600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ

|±0.4%rdg±1dgt (Basic accuracy) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Continuity buzzer |
 |
 |
 |
600.0Ω (The buzzer turns on for resistances lower than 50±30Ω) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Diode test |
 |
 |
 |
2.000V |±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Capacitance |
 |
 |
 |
10.00/100.0nF/1.000/10.00/100.0/1000µF

|±2%rdg±5dgt (Basic accuracy) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Frequency |
 |
 |
 |
10.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz

|±0.02%rdg±1dgt (Basic accuracy) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Temperature |
 |
 |
 |
-50 - 600ºC |±2%rdg±2ºC (with the use of K-type Temperature probe) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Other functions |
 |
 |
 |
Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Withstand voltage |
 |
 |
 |
6,880V/5 sec. |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Applicable
standards |
 |
 |
 |
IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Power source |
 |
 |
 |
R6 (1.5V)×4 (Auto power off: approx. 20 minutes) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Dimensions |
 |
 |
 |
192(L)×90(W)×49(D) mm |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Weight |
 |
 |
 |
Approx. 560g (including batteries) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Accessories |
 |
 |
 |
7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included) |
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
* Only for KEW 1052 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Description |
 |
 |
 |
Model |
 |
 |
 |
Specification |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Crocodile clip test lead |
 |
 |
 |
7234 |
 |
 |
 |
CAT IV 600V, CAT III 1000V |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
AC/DC Clamp Sensor |
 |
 |
 |
8115 |
 |
 |
 |
AC 130A/DC 180A |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
USB Communication set |
 |
 |
 |
8241 |
 |
 |
 |
USB adaptor + USB cable + DMM Software |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
DMM Printer full set |
 |
 |
 |
8249 |
 |
 |
 |
8243 + 8246 + 8248 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Printer Communication set |
 |
 |
 |
8243 |
 |
 |
 |
Printer Adapter + RS232 cable |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Printer |
 |
 |
 |
8246 |
 |
 |
 |
Printer + Thermal paper (1 roll) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
AC adapter for printer [EU] |
 |
 |
 |
8248 |
 |
 |
 |
AC230V±10% |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Thermal paper for printer |
 |
 |
 |
8247 |
 |
 |
 |
10 rolls |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Temperature probes |
 |
 |
 |
8405 |
 |
 |
 |
Max. 500ºC
(Surface type, Point material: Ceramic) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
8406 |
 |
 |
 |
Max. 500ºC (Surface type) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
8407 |
 |
 |
 |
Max. 700ºC (Liquid, Semi-solid) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
8408 |
 |
 |
 |
Max. 600ºC (Air, Gas) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Carrying case |
 |
 |
 |
9154 |
 |
 |
 |
for the main unit with testi leads and communication cable |
 |
 |
 |
 |
 |
 |
 |
 |
 |

|
|
|