Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Operating system | AC potentiometer method, 3-pole measurement, 2-pole measurement Note: When using 2-pole method, applies only when the measurement range of 100 Ω (0 to 115 Ω) and 1000 Ω (0 to 1150 Ω) |
||
---|---|---|---|
Measurement range | 10 Ω (0 to 11.5 Ω) | 100 Ω (0 to 115 Ω) | 1000 Ω (0 to 1150 Ω) |
Accuracy | ±2.5 % f.s. | ±2.5 % f.s. | ±2.5 % f.s. |
Earth voltage | 30 V (0 to 30 V), Accuracy: ±3.0 % f.s. | ||
Functions | Switchable testing frequency (575 Hz, or 600 Hz), Auxiliary earthing (P/C pole) resistance check | ||
Power supply | R6P (AA) manganese battery ×6 (Continuous use: 350 times), or LR6 (AA) alkaline battery ×6 (Continuous use: 1100 times) (at 30 sec measurement/ 30 sec pause cycle) | ||
Dimensions and mass | 164 mm (6.46 in) W × 119 mm (4.69 in) H × 88 mm (3.46 in) D, 800 g (28.2 oz) | ||
Accessories | Auxiliary Earthing Rod 9214 ×2, Measuring Cable 9215 (Black 5 m (16.41 ft), Yellow 10 m (32.81 ft), Red 20 m (65.62 ft), each one, Cable winder×3), Carrying Case 9393 ×1, Hand strap ×1, R6P (AA) manganese battery ×6, Instruction manual ×1 |