- Auto setting digital storage scope 5 MHz
- Frequency counter up to 1.3 GHz
- Function generator up to 5Mhz
- Logic analyzer
- Display 160 by 160 pixel graphic LCD (63mm x 63 mm)
- Measurement rate: 4 times/second for digital, 7 times/second for bar-graph
- Direct print capability through recommended thermal printer
- Auto power-off after 30 minutes, set up mode (enable/disable)
- RS 232 computer interface: 1200, 2400, 4800, 9600 bps baud rates, 8 bit data, 1 stop bit, none parity bit
- Store up to 15 screens either text or graph
- HELP key
- Automatic Testing System & Memory
- 4 directions cursor
- Set up for printer, parity, beeper, back light, baud rate, dBm reference, sleep mode
- User manual in SET UP
- Frequency counter displays hold mode and rpm
- Display ”OVER” with beeper sound for over range indication
DMM
|
||||
AC Current (True RMS) (auto/manual) | ||||
Range
|
Resolution
|
Accuracy
|
Overload Protection |
|
50Hz ~ 1kHz
|
1kHz ~ 10kHz
|
|||
40mA | 10µA |
±(1.2% rdg + 10 dgts)
|
±(4.0% rdg + 10 dgts)
|
250V/500mA fused
|
400mA | 100µA | |||
4A | 1mA |
±(2.0% rdg + 10 dgts)
|
±(4.0% rdg + 10 dgts)
|
250V/20A fused
|
20A | 10mA | |||
AC Voltage (True RMS) | ||||
Range
|
Resolution
|
Accuracy
|
||
50Hz ~ 1kHz
|
1kHz ~ 10kHz
|
10kHz ~ 30 KHz
|
||
400mV | 0.1mV |
±(1.0% rdg + 10 dgts)
|
±(5.0% rdg + 10 dgts)
|
ns
|
4V | 1mV |
±(0.75% rdg + 10 dgts)
|
±(2.0% rdg + 10 dgts)
|
±(5.0% rdg + 10 dgts)
|
40V | 10mV |
±(0.75% rdg + 10 dgts)
|
±(1.0% rdg + 10 dgts)
|
±(5.0% rdg + 10 dgts)
|
400V | 100mV |
±(0.75% rdg + 10 dgts)
|
±(1.0% rdg + 10 dgts)
|
±(5.0% rdg + 10 dgts)
|
700V | 1V |
±(1.0% rdg + 10 dgts)
|
ns
|
ns
|
DC Current (auto / manual) | ||||
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
|
40mA | 10µA |
±(1.2% rdg + 10 dgts)
|
250V/500mA fused
|
|
400mA | 100µA | |||
4A | 1mA |
±(1.5% rdg + 10 dgts)
|
250V/20A fused
|
|
20A | 10mA | |||
DC Voltage (auto / manual) | ||||
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
Overload Protection
|
400mV | 0.1mV |
±(0.3% + 5 digits)
|
10MΩ
|
1000V DC or AC peak with 10 seconds
|
4V | 1mV | |||
40V | 10mV | |||
400V | 100mV | |||
1000V | 1V | |||
Resistance | ||||
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
|
400Ω | 0.1Ω |
±(0.5% + 10 digits)
|
250V DC or AC peak within 10 seconds
|
|
4kΩ | 1Ω | |||
40kΩ | 10Ω | |||
400kΩ | 100Ω | |||
4MΩ | 1kΩ | |||
40MΩ | 10kΩ |
±(1.0% + 5 digits)
|
||
Capacitance
|
||||
Range
|
Resolution
|
Accuracy
|
||
40n/400n/ 4µ/40µ/ 100µF |
0.01n/0.1n/ 1n/10n/ 100nF |
±(2.0% + 10 digits)
|
||
Diode Test | Resolution 1mV, Accuracy ±(2.0% rdg ± 5 dgts), Max 5V Open Circuit | |||
Continuity | If continuity exists ≤ 60Ω, built in buzzer will sound | |||
Display | 3¾ digits, 3999 counts |
Digital Storage Oscilloscope
|
|||
Rising Time | Less than 15nS | ||
Input Impedance | 1MΩ | ||
Vertical | Number of Channel | 1 channel | |
Sensitivity | 10mV/div - 200V/div (14 divisions) | ||
Bandwith | DC to 5MHz | ||
Sample Rate | 25 x 106 samples/s | ||
Input Protection | 600Vpp | ||
Horizontal | Sweep : 125ns ~ 2s/div (23 divisions), Mode : Auto | ||
Trigger | Auto / Manual with slope | rising, falling | |
Trigger Adjustable | 15% ~ 85% | ||
Input Impedance | CH A 1MΩ; CH B 50MΩ | ||
Maximum Input Voltage | CH A 100Vpp; CH B 5Vpp | ||
Simultaneously display frequency, period, and rpm | |||
Frequency Counter
|
|||
Range | 5Hz ~ 1.3GHz | ||
Display | 8 digits | ||
Period Measurement | 5Hz ~ 100MHz | ||
Internal Gate Time | 0.1s, 1s, 10s | ||
Input Measurement | CH A : 5Hz ~ 40MHz ; CH B : 40MHz ~ 1.3GHz | ||
Input Sensitivity | 5Hz ~ 10MHz | 100mVrms | |
10MHz ~ 40MHz | 200mVrms | ||
40MHz ~ 80MHz | 300mVrms | ||
80MHz ~ 1.3GHz | 200mVrms | ||
Min/Max/Avg |
Records min, max, and average; History graph display | ||
Hold | Captures current reading | ||
Peak Hold | Records peak max, min; History graph display | ||
Function Generator
|
|||
Output | Sine, triangle, square wave | ||
Range | 40Hz ~ 50MHz (6 range) | ||
Display | 3 digits | ||
Output Impedance | 600Ω | ||
Amplitude | 2 ~ 10Vpp | ||
Duty Cycle | 25% ~ 75% | ||
Display frequency, period, duty cycle, and amplitude simultaneous in one screen | |||
Logic Analyzer
|
|||
Vertical | Input Channel |
1 channel |
|
Input Impedance | 1MΩ | ||
Protection Level | 50Vpp Max | ||
Horizontal | Sweep time : 125ns - 2s/div (23 divisions), Mode : Auto | ||
General Spesifications
|
|||
Power | 6 AA cells (9V Alkaline) or 6 A (7.2V) Ni-Cd battery or 2 rechargeable Ni-Cd battery pack or AC Adapter with internal charger | ||
Size / Weight | H220 x W107 x D55mm / Approx. 800g | ||
Standard Accessories | Alligator Clip Set, Test Leads, Holster, AC/DC Power Adaptor with Internal Charger, Ni-Cd Battery Pack, Scope Probe (1:1), BNC/Banana Adaptor, RS232 Interface Cable with Software, Manual, Constant Certificate. | ||
Optional Accessories | AC Current Adapter, Humidity Adapter, Temperature Adapter, Thermal Printer, Deluxe Carrying Bag, Certificated of Calibration. |