Properties
Control of standard components
Temperature |
2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value |
Humidity |
active humidifying and de-humidifying control (20-95 %) with digital display of relative humidity - resolution of display 0.5 %, setting accuracy 1 % |
Humidity |
humidity supply with distilled water from external tank by self-priming pump |
Humidity |
active humidifying and de-humidifying adjustable from 20-95 % rh with digital display of relative humidity - resolution of display 0.5 %, setting accuracy 1 % |
Humidity |
humidity supply with distilled water from external tank by self-priming pump |
Humidity |
humidification by hot steam generator |
Controller |
digital display of all set parameters, such a temperature, weekdays, time, CO2, humidity and set-up values - language to be chosen via set-up |
Controller |
Electronic microprocessor temperature controller with auto-diagnostic system |
Timer |
integrated timer for tempering profiles of up to 40 ramps each, each segment adjustable from 1 min. to 999 hrs. |
Timer |
digital 7-day programme timer with real time clock, precise minute setting |
Temperature
resolution of display for setpoint values 0.1°C up to 99.9°C, 0.5°C from 100°C and for actual values 0.1°C (LED) |
with humidity min. 8°C above ambient up to +90°C |
without humidity min. 8°C above ambient up to +160°C |
Control technology
Calibration |
three freely selectable temperature values |
Ventilation
uniform atmosphere and temperature distribution owing to enclosed non-turbulent ventilation system in working chamber |
Communication
Interface |
USB-interface incl. Memmert software "Celsius" for programming and documentation |
Documentation |
integrated ring memory as data logger for GLP-conforming long-term documentation of all relevant parameters - 1024 kB |
Documentation |
programme stored in case of power failure |
Documentation |
parallel printer interface (incl. real time clock with date function) for all PCL3-compatible ink jet printers for GLP-conforming documentation |
Programming |
chip-card control incl. 1 MEMoryCard XL with 32 kB storage capacity (max. 40 ramps) |
Safety
Temperature control |
mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 10°C above nominal temperature |
Temperature control |
overtemperature monitor TWW, protection class 3.1 or adjustable temperature limiter TWB, protection class 2, selectable on display |
AutoSAFETY |
additionally integrated over- and undertemperature monitor "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature |
Autodiagnostic system |
integral fault diagnostics for temperature and humidity control |
Alarm |
with visual and acoustic alarm in case of over-/under temperature and underhumidity, open door and empty water tank |
Alarm |
visual and acoustic |