Other features and functions of importance are:
Graphical, large and high resolution LCD display with backlit.
Automatic UNIT CONVERSIONS in many specific units for each type of transducers.
Function MULTIMETER which displays the signal of the sensor directly in mV/V, V or mA.
User selectable language : ITALIAN or ENGLISH.
Function ZERO and AUTOZERO to reset automatically the measure if the measurement is below a set threshold.
Function of HOLD, PEAK, programmable FILTER.
Function of DISCHARGE in order to measure the amount of product discharged for example from a tank.
Function TOTAL to perform the sum of the channels.
Function KEY LOCK to protect the instrument settings by unauthorized persons.
Function CLOCK-CALENDAR (Option) with date and time.
24 columns PRINTER (option) connected to the serial port through which it is possible to print the measuring points with the date and time and the data of the company that carried out the survey.
Graphical, large and high resolution LCD display with backlit.
Automatic UNIT CONVERSIONS in many specific units for each type of transducers.
Function MULTIMETER which displays the signal of the sensor directly in mV/V, V or mA.
User selectable language : ITALIAN or ENGLISH.
Function ZERO and AUTOZERO to reset automatically the measure if the measurement is below a set threshold.
Function of HOLD, PEAK, programmable FILTER.
Function of DISCHARGE in order to measure the amount of product discharged for example from a tank.
Function TOTAL to perform the sum of the channels.
Function KEY LOCK to protect the instrument settings by unauthorized persons.
Function CLOCK-CALENDAR (Option) with date and time.
24 columns PRINTER (option) connected to the serial port through which it is possible to print the measuring points with the date and time and the data of the company that carried out the survey.
For each input channel, you can calibrate the signal coming from the sensor both in the POSITIVE RANGE and in the NEGATIVE RANGE (Example in tension and compression) through 3 different modes:
Calibration with Full Scale: characterization through the programming of the transducer full scale and sensitivity in both the positive and negative range.
Calibration for POINTS: linearity correction by programming 5 known points in both the positive and negative range.
Known Weight: practice characterization (in the field) by imposing a known weight, pressure, torque to the sensor and calibrating the transducer output to this reference value.
Calibration with Full Scale: characterization through the programming of the transducer full scale and sensitivity in both the positive and negative range.
Calibration for POINTS: linearity correction by programming 5 known points in both the positive and negative range.
Known Weight: practice characterization (in the field) by imposing a known weight, pressure, torque to the sensor and calibrating the transducer output to this reference value.
To increase security the instrument has the ability to perform a BACKUP of all calibrations data so that you can recall them in case of accidental tampering.