The disposable probes are manufactured from robust polycarbonate, and can either be disposed of after each sample or autoclaved, up to seven times. Ideal where cross sample contamination is of concern. Please note that it is necessary to use the disposable probe adaptor SHM/ADAPT, available separately, to use these probes with both the SHM1 and SHM2.
The stainless steel probes are available in a variety of sizes to suit your processing needs, all are precision engineered and suitable for autoclaving. The stainless steel 5mm probe comes with a flat end, all other probes have a saw tooth end and are capable of processing hard or frozen tissue.
Model | SHM/5 | SHM/7 | SHM/10 | SHM/20 | SHM/DISP |
---|---|---|---|---|---|
Size | 5mm | 7mm | 10mm | 20mm | 7mm |
Type | Flat head | Saw tooth | Saw tooth | Saw tooth | Saw Tooth |
Length | 75mm | 115mm | 115mm | 195mm | 110mm |
Processing | 0.03ml - 5ml | 0.25ml - 30ml | 1.5ml - 100ml | 50ml - 2L | 0.25 - 30ml |
Stand and Accessories
The SHM/STAND has been purpose built to hold the Stuart® homogenisers, it couples directly to the SHM2 and attaches to the SHM1 clamp holder, included with SHM1. The stand is heavy duty to remain stable during use and comes with a rubber coated base to help stabilise samples during processing.
Base, mm (wxdxh) | 220 x 304 x 11 |
---|---|
Rod, mm (ø x h) | 16 x 610 |
Net Weight, kg | 3.6 |
Ordering Information
Model | Description |
---|---|
SHM/5 | 5mm Stainless steel probe |
SHM/7 | 7mm Stainless steel probe |
SHM/10 | 10mm Stainless steel probe |
SHM/20 | 20mm Stainless steel probe |
SHM/DISP | Disposable probes, pack of 25 |
SHM/ADAPT | Adaptor for disposable probes |
SHM/STAND | Stand compatible with SHM1 and SHM2 |
SHM/TOOL | Replacement tool kit to disassemble stainless probes |
Replacement Bearing part numbers
Generator | Diameter | Length | Shaft | Upper Bearing | Lower Bearing | Mid Bearing |
---|---|---|---|---|---|---|
SHM/ 5 | 5mm | 95mm | SHM/ 5SHAFT | SHM10503 | SHM10505 | n/ a |
SHM/ 7 | 7mm | 115mm | SHM/ 7SHAFT | SHM10503 | SHM10507 | SHM10071 |
SHM/ 10 | 10mm | 115mm | SHM/ 10SHAFT | SHM10503 | SHM10504 | SHM10069 |
SHM/ 20 | 20mm | 195mm | SHM/ 20SHAFT | SHM10503 | SHM10503 | SHM10069 |
Over time, and with repeated use, Teflon bearings will wear out and must be replaced. Failure to replace worn Teflon bearings will result in damage to the homogenisr probe. Teflon bearings should be replaced when they no longer fit snugly against the rotor shaft, or when visible wear is apparent, or if black particles become visible in the sample. Any damage incurred through failure to replace worn bearings will invalidate your homogeniser probe warranty.