Improved and intuitive design
The TL23 Series’ large full color touch screen display and intuitive user interface accelerate setup, calibration and measurement. An easy interface and guided procedures give you confidence in your results.
A smart device for more reliable measurements
The TL23 Series ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements.
Easy to use. Easy to Be Right
The TL23 Series provides everything you need at your fingertips. With a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance, Hach® makes it easy to Be Right.
Specifications
Accuracy:Ratio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU based on formazin primary standard
Ratio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU
Ratio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU
Air Purge:Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975)
0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max
Hose barb connection for 1/8-inch tubing
0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max
Hose barb connection for 1/8-inch tubing
Certifications:CE, KC, RCM
Communication:USB
Data Logging:2000 total logs, includes reading log, verification log and calibration log
Dimensions (H x W x D):153 mm x 395 mm x 305 mm
Display:17.8 mm (7 in.) color touch screen
Interface:2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner
Light Source:Tungsten filament lamp
Measurement Method:Nephelometric
Operating Temperature Range:0 to 40 °C (32 to 104 °F)
Power Requirements (Amps):3.4 A
Power Requirements (Hz):50/60 Hz
Power Requirements (Voltage):100 - 240 VAC
Range:NTU (Ratio on): 0 - 4000
NTU (Ratio off): 0 - 40
EBC (Ratio on): 0 - 980
EBC (Ratio off): 0 - 9.8
NTU (Ratio off): 0 - 40
EBC (Ratio on): 0 - 980
EBC (Ratio off): 0 - 9.8
Reading Modes:Single, continuous, Rapidly Settling Turbidity™, signal averaging on or off, ratio on or off
Regulatory:Meets EPA Method 180.1
Repeatability:±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)
Resolution:Turbidity: 0.001 NTU/EBC (on lowest range)
Response Time:Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)
Sample Cell Compatibility:Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps
Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.
Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.
Sample Requirements:25 mm sample cell: 20 mL minimum
0 to 70 °C (32 to 158 °F)
0 to 70 °C (32 to 158 °F)
Stabilization Time:Ratio on: 30 minutes after start-up
Ratio off: 60 minutes after start-up
Ratio off: 60 minutes after start-up
Storage Conditions:-20 to 60 °C
Units:NTU and EBC
Weight:6.61 lbs. (3.0 kg)