HACH TL2360 Turbidity Meter ISO Series

Harga :
CALL
Merk :
HACH
Pengiriman :
3 hari sejak pembayaran
Lokasi :
Jawa Barat - Bekasi
Dilihat :
70 Kali
Update Terakhir :
02-09-2016 10:49

Detail Produk

 

 Specifications

Accuracy:FNU: ±2% of reading plus 0.01 FNU from 0 - 1000 FNU

FAU: ±10% of reading from 20 - 10000 NTU

NTU: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU, ±10% of reading from 4000 - 10000 NTU
Accuracy 3:Absorbance: ±0.005 Abs from 0 - 1 Abs at 860 nm

Transmittance: 0.12% T from 10 - 100% T at 860 nm
Air Purge:Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975)
0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max
Hose barb connection for 1/8-inch tubing
Certifications:CE, KC, RCM
Communication:USB
Data Logging:2000 total logs, includes reading log, verification log and calibration log
Dimensions (H x W x D):153 mm x 395 mm x 305 mm
Display:17.8 mm (7 in.) color touch screen
Interface:2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner
Light Source:Light-emitting diode (LED) at 860 ± 30 nm
Measurement Method:Nephelometric
Operating Temperature Range:0 to 40 °C
Power Requirements (Amps):3.4 A
Power Requirements (Hz):50/60 Hz
Power Requirements (Voltage):100 - 240 VAC
Range:FNU (Ratio on): 0 - 1000

FNU (Ratio off): 0 - 40

FAU (auto range): 20 - 10000

NTU (Ratio on): 0 - 10000 auto decimal

NTU (Ratio off): 0 - 40

EBC (Ratio on): 0 - 2450 auto decimal

EBC (Ratio off): 0 - 9.8

Absorbance (auto range): 0 - 2.00

Transmittance (%): 1.0 - 100

Degree (mg/L): 0 - 100
Reading Modes:Manual or auto range, signal averaging on and adjustable or off, ratio on or off
Regulatory:Meets ISO 7027, DIN EN 27027, DIN 38404 and NFT 9033
Repeatability:±1% of reading or 0.01 FNU/NTU, whichever is greater (under reference conditions)
Resolution:Turbidity: 0.001 FNU/NTU/EBC
Absorbance: 0.004 Abs
Transmittance: 0.8% T
Response Time:Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)
Sample Cell Compatibility:Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps

Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.
Sample Requirements:25 mm sample cell: 20 mL minimum
0 to 70 °C (32 to 158 °F)
Stabilization Time:Immediately
Storage Conditions:-20 to 60 °C
Units:FNU, FAU, NTU, EBC, Abs (absorbance), %T (% transmittance) and mg/L
Weight:6.61 lbs. (3.0 kg)