Jawa Barat - Bekasi

Fluke 1623 Basic GEO Earth Ground Tester

Harga :
CALL
Merk :
FLUKE
Lokasi :
Jawa Barat - Bekasi
Dilihat :
54 Kali
Update Terakhir :
13-09-2016 10:02

Detail Produk

 FEATURES 

  • One-button measurement concept
  • 3- and 4-pole earth ground measurement
  • 4-pole soil resistivity testing
  • Selective testing, no disconnection of ground conductor (1 clamp)
  • Stakeless testing, quick ground loop testing (2 clamps)
  • Measuring frequency 128 Hz

SPECIFICATIONS 

RA 3-pole Ground Resistance Measurement (IEC 1557-5)
Measuring voltage Vm = 48 V ac
Short circuit current > 50 mA
Measure frequency 128 Hz
Resolution 0.001 Ω to 10 Ω
Measuring range 0.001 Ω to 19.99 kΩ
Intrinsic error ± (2 % of reading + 3 digit)
Operating error ± (5 % of reading + 3 d)
RA 4-pole Ground Resistance Measurement (IEC 1557-5)
Measuring voltage Vm = 48 V ac
Short circuit current > 50 mA
Measure frequency 128 Hz
Resolution 0.001 Ω to 10 Ω
Measuring range 0.001 Ω to 19.99 kΩ
Intrinsic error ± (2 % of reading + 3 d)
Operating error ± (5 % of reading + 3 d)
RA 3-pole Ground Resistance Measurement With Current Clamp
Measuring voltage Vm = 48 V ac
Short circuit current > 50 mA
Measure frequency 128 Hz
Resolution 0.001 Ω to 10 Ω
Measuring range 0.001 Ω to 19.99 kΩ
Intrinsic error ± (7 % of reading + 3 d)
Operating error ± (10 % of reading + 5 d)
RA 4-pole Selective Ground Resistance Measurement With Current Clamp
Measuring voltage Vm = 48 V ac
Short circuit current > 50 mA
Measure frequency 128 Hz
Resolution 0.001 Ω to 10 Ω
Measuring range 0.001 Ω to 19.99 kΩ
Intrinsic error ± (7 % of reading + 3 d)
Operating error ± (10 % of reading + 5 d)
Stakeless Ground Loop Measurement
Measuring voltage Vm = 48 V ac
Measure frequency 128 Hz (125 Hz on request)
Noise current (Iext) Max. Iext = 10 A (ac) (RA < 20 Ω)
Max. Iext = 2 A (ac) (RA < 20 Ω)
Resolution 0.001 Ω to 0.1 Ω
Measuring range 0.001 Ω to 199.9 kΩ
Intrinsic error ± (7 % of reading + 3 d)
Operating error ± (10 % of reading + 5 d)
Environmental Specifications
Working temperature -10 °C to +50 °C
Operating temperature 0 °C to +35 °C
Nominal temperature +18 °C to +28 °C
Storage temperature -20 °C to +60 °C
Climatic class C1 (IEC 654-1), -5 °C to + 45 °C, 5 % to 95 % RH
Protection type IP56 for case, IP40 for battery door according to EN 60529
Safety Specifications
Safety rating CAT II, 300 V
Mechanical And General Specifications
Display 1999 digit LCD – display with special symbols, digit height 25 mm, fluorescent backlight
Size 133 mm x 187 mm x 250 mm
Weight 1.1 kg (including batteries)
Warranty Two years
Battery life Typical > 3000 measurements

Permintaan Penawaran