Fluke 1625 Kit - Advanced Geo Earth Ground Tester
Pengiriman :
3 hari sejak pembayaran
Lokasi :
Jawa Barat - Bekasi
Update Terakhir :
13-09-2016 10:22
Detail Produk
FEATURES
- 4-pole earth ground measurement
- 4-pole soil resistivity testing
- 2-pole resistance measurement AC
- 2- and 4-pole resistance measurement DC
- Selective testing, no disconnection of ground conductor (1 clamp)
- Stakeless testing, quick ground loop testing (2 clamps)
- Earth impedance measurement at 55 Hz
- Automatic frequency control (AFC) (94, 105, 111, 128 Hz)
- Measuring voltage switchable 20/48V
- Programmable limits, settings
- Continuity with buzzer
SPECIFICATION
RA 3-pole Ground Resistance Measurement (IEC 1557-5) |
Measuring voltage |
Vm = 20/48 V AC |
Short circuit current |
250 mA AC |
Measure frequency |
94, 105, 111, 128Hz |
Resolution |
0.001 Ω to 100 Ω |
Measuring range |
0.001 Ω to 299.9 kΩ |
Intrinsic error |
± (2 % of reading + 2 d) |
Operating error |
± (5 % of reading + 5 d) |
RA 4-pole Ground Resistance Measurement (IEC 1557-5) |
Measuring voltage |
Vm = 20/48 V AC |
Short circuit current |
250 mA AC |
Measure frequency |
94, 105, 111, 128Hz |
Resolution |
0.001 Ω to 100 Ω |
Measuring range |
0.001 Ω to 299.9 kΩ |
Intrinsic error |
± (2 % of reading + 2 d) |
Operating error |
± (5 % of reading + 5 d) |
RA 3-pole Ground Resistance Measurement With Current Clamp |
Measuring voltage |
Vm = 20/48 V AC |
Short circuit current |
250 mA AC |
Measure frequency |
94, 105, 111, 128Hz |
Resolution |
0.001 Ω to 10 Ω |
Measuring range |
0.001 Ω to 29.99 kΩ |
Intrinsic error |
± (7 % of reading + 2 d) |
Operating error |
± (10 % of reading + 5 d) |
RA 4-pole Selective Ground Resistance Measurement With Current Clamp |
Measuring voltage |
Vm = 20/48 V AC |
Short circuit current |
250 mA AC |
Measure frequency |
94, 105, 111, 128Hz |
Resolution |
0.001 Ω to 10 Ω |
Measuring range |
0.001 Ω to 29.99 kΩ |
Intrinsic error |
± (7 % of reading + 2 d) |
Operating error |
± (10 % of reading + 5 d) |
Stakeless Ground Loop Measurement |
Measuring voltage |
Vm = 20/48 V ac |
Measure frequency |
94, 105, 111, 128Hz |
Noise current (Iext) |
Max. Iext = 3 A |
Resolution |
0.001 Ω to 10 Ω |
Measuring range |
0.001 Ω to 29.99 kΩ |
Intrinsic error |
± (7 % of reading + 2 d) |
Operating error |
± (10 % of reading + 5 d) |
Environmental Specifications |
Working temperature |
-10 °C to +50 °C |
Operating temperature |
0 °C to +35 °C |
Nominal temperature |
+18 °C to +28 °C |
Storage temperature |
-30 °C to +60 °C |
Climatic class |
C1 (IEC 654-1), -5 °C to + 45 °C, 5 % to 95 % RH |
Protection type |
IP56 for case, IP40 for battery door according to EN 60529 |
Safety Specifications |
Safety rating |
CAT II, 300 V |
Mechanical And General Specifications |
Display |
2999 Digit LCD – 7 segment liquid crystal display with special symbols and backlight |
Size |
133 mm x 187 mm x 250 mm |
Weight |
1.1 kg (including batteries) |
Warranty |
Two years |
Battery life |
Typical 3000 measurements (RE+RH ≤ 1 kΩ) |
Typical 6000 measurements (RE+RH ≤ 10 kΩ) |