Digital Multimeters
KEW 1012
• True RMS can measure and indicate distorted waveforms
• 6040 counts with Bar Graph display
• MIN/MAX function enables to record min & max value
• REL(relative value) function to indicate the measurement variation
DC V | 600.0mV/6.000/60.00/600.0/600V (Input Impedance: 10MΩ, 100MΩ only 600mV) ±0.5%±2dgt (600.0mV/6.000/60.00/600.0V) ±0.8%±3dgt (600V) |
---|---|
AC V | 6.000/60.00/600.0/600V (Input Impedance: 10MΩ) ±1.5%±5dgt (6.000V) ±1.2%±3dgt (60.00/600.0V) ±1.5%±5dgt (600V) |
DC A | 600/6000µA/60/600mA/6/10A ±1.2%±3dgt (600/6000µA/60/600mA) ±2.0%±5dgt (6/10A) |
AC A | 600/6000µA/60/600mA/6/10A ±1.5%±4dgt (600/6000µA/60/600mA) ±2.2%±5dgt (6/10A) |
Ω | 600Ω/6/60/600kΩ/6/60MΩ ±1.0%±2dgt (600Ω/6/60/600kΩ/6MΩ) ±2.0%±3dgt (60MΩ) |
Continuity buzzer | 0 - 600Ω (Buzzer sounds below 100Ω) |
Diode test | 2.8V Release Voltage:Approx. 0.4mA Test Current |
Capacitance | 40/400nF/4/40/400/4000µF |
Frequency | 10/100/1000Hz/10/100/1000kHz/10MHz |
DUTY | 0.1 - 99.9% (Pulse width/Pulse period) ±2.0%±2dgt (- 10kHz) |
Applicable standards | IEC 61010-1 CAT III 300V Pollution degree 2 IEC 61010-1 CAT II 600V Pollution degree 2 IEC 61010-031 IEC 61326 |
Display | 6040 Counts |
Power source | R6 (1.5V) × 2 (Auto-power-OFF within 15 minutes) |
Dimensions | 161(L) × 82(W) × 50(D)mm |
Weight | Approx. 280g |
Included Accessories | 7066A (Test leads) 0.8A/600V (Ceramic Fuse) × 1built-in 10A/600V (Ceramic Fuse) × 1built-in R6 × 2 Instruction Manual |
Optional Accessories | 7234 (Crocodile clip test lead) 9095 (Carrying case) |