AC Digital Clamp Meters
KEW 2204R
• Flexible and light weight clamp sensor
• MIN MAX function
• Backlight LCD display
• IEC 61010-1 (CAT IV 600V /CAT III 1000V)
• True RMS
AC A (RMS) | ||
---|---|---|
Range | 4.000/40.00/400.0A | |
Accuracy | ±3%rdg±5dgt[45-500Hz] (At the center of the circle formed by the flexible sensor) |
|
Crest factor (CF) |
Full scale CF<1.6, half scale<3.2 Effective input crest values are √2 times of the max values of each range. |
|
Conductor size | Ø70mm max. | |
Influence of Conductor position |
Additional ±2% (max.) depending on the distance from the center position | |
Overload protection | 500A AC for 10 seconds | |
Applicable standards | IEC 61010-1, IEC 61010-2-032 CAT Ⅳ 600V / CAT Ⅲ 1000V Pollution degree 2 IEC 61326-1(EMC) , IEC 60529 IP40 , EN50581(RoHS) |
|
Operating temperature & humidity |
0 - +50℃,less than 80% RH (without condensation) | |
Storage temperature & humidity |
-10 - +60℃,less than 70% RH (without condensation) | |
Power source | R03 / LR03(AAA)(1.5V)×2 ※Continuous measuring time:approx.120hours (Auto power off:approx.15 minutes) |
|
Dimensions | 120(L)×70(W)×26(D):Display unit φ5.5mm approx.:Cable diameter 1.8m approx.:Cable length |
|
Weight | 200g approx. (including batteries) | |
Included Accessories | 9174 (Carrying case) LR03(AAA)×2, Insruction manual |
|