AC/DC Digital Clamp Meters
MODEL 2010
• High sensitivity, miniature AC/DC clamp meter.
• 0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
• Output terminal for recorder connection.
Never make current measurement on a circuit above 60V AC/DC
as the instrument is designed for use on low voltage circuits only.
AC A | 200mA/2/20A ±1%rdg±2dgt [50/60Hz] (200mA) ±1.5%rdg±8dgt [40Hz - 2kHz] (200mA) ±1%rdg±2dgt [50/60Hz] (2A) ±2.5%rdg±10dgt [40Hz - 2kHz] (2/20A) |
---|---|
DC A | 2/20A ±1%rdg±2dgt (2A) ±1.5%rdg±4dgt (20A) |
Conductor size | Ø7.5mm max. |
Frequency response | DC, 40Hz - 2kHz |
Output | Recorder : DC200mV against AC200mA/2/20A DC200mV against DC2/20A |
Power source | 6LF22(9V) × 1 or AC Adaptor |
Dimensions | 142(L) × 64(W) × 26(D)mm 153(L) × 23(W) × 18(D)mm Clamp Sensor |
Weight | 220g approx. |
Included Accessories | 9071 (Carrying Case) Alkaline 6LF22 × 1 Instruction Manual |
Optional Accessories | 8022 (AC Adaptor) (110V) 8023 (AC Adaptor) (220V) 7256 (Output cord) |