KYORITSU Digital Insulation / Continuity Tester 3007A
Harga :
CALL
Merk :
KYORITSU
Pembelian Minimal :
1 unit
Pengiriman :
1 hari sejak pembayaran
Lokasi :
Jawa Barat - Bekasi
Dilihat :
137 Kali
Update Terakhir :
25-07-2017 14:03
Detail Produk
•
Bargraph to display insulation resistance.
•
Displays the value of external AC voltage along with flashing symbol.
•
Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
•
Trac-Lok mode to conserve battery life on insulation and continuity tests.
•
Live circuit warning beeper.
•
Releasing the test button automatically discharges the charges stored in the circuit under test.
•
Backlight function to view the test results in dimly lit areas.
•
200mA continuity measuring current to IEC 61557.
•
Minimum 1mA current on insulation tests to IEC 61557.
Insulation Resistance
Test Voltage
250V/500V/1000V
Measuring Ranges
(Mid-scale Value)
20MΩ/200MΩ/2000MΩ
Output Voltage
on open circuit
Rated test voltage+20%, -0%
Nominal Current
1mA DC min.
Output Short
Circuit Current
1.5 mA DC approx.
Accuracy
|
±1.5%rdg±5dgt (20MΩ/200MΩ)
|
±10%rdg±3dgt (2000MΩ)
Continuity Test
Measuring Ranges
(Mid-scale Value)
20Ω/200Ω/2000Ω
Output Voltage
on open circuit
7 - 12V DC
Measuring Current
200mA DC min.
Accuracy
|
±1.5%rdg±5dgt (20Ω)
|
±1.5%rdg±3dgt (200Ω/2000Ω)
AC Voltage
AC Voltage range
0-600V AC
Accuracy
|
±5%rdg±3dgt
General
Safety Standard
IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031 IEC 61557-1/2/4
IP Rating
IEC 60529-IP54
EMC Standard
IEC 61326-1
Withstand Voltage
3700V AC for 1 minute
Power Source
R6 (AA) (1.5V) × 8
Dimensions
185(L) × 167(W) × 89(D)mm
Weight
990g approx
Accessories
7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 8
Shoulder Strap
Instruction Manual
Permintaan Penawaran
Kategori Produk
RETSCH
WALKER
SEW
HANH SHIN
IWAKI
DURAN
HACH
SDI
PARTECH
OHAUS
GW Instek
DAIHAN
CAMAX
DOA
WTW
STUART
test equipment
LUDWIG SCHNEIDER
AEMC
ROBIN AIR
DAIHAN
RETSCH
EXTECH
COOL BOX
AEP TRANSDUCERS
EPPENDORF
HOLDPEAK
EUTECH
E- INSTRUMENT
SK - SATO
HANNA
analox
ELMA
RM - YOUNG
SANWA
MEMMERT
MEMMERT
KOEHLER
LUTRON
CONSTANT
IRTEK
HYDRION
HIOKI
HYDROBIOS
FLUKE
HACH
AIRMAR
HAZDUST
KYORITSU
ASSEMBLAD
JENCO
JEKEN
SHINAGAWA
MITECH
Link
Samudramall